Sunday, May 24, 2009

Broadband Incident Report : : MANCHESTER WOODLEY MUX 101 : PARTIAL LOSS OF SERVICE : Reference 13128 : Issue 3 :

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
--------------------------------------------------------------

  BT Wholesale - Broadband Incident Report  
     
  Please read the following incident report as it could have an impact on some of your end users  
     
  BT Incident Reference: 13128   Issue : 3  
  Detected Date: 24/05/2009   Detected Time: 03:20  
  Start Date: 24/05/2009   Start Time: 01:19  
  Anticipated Clear Date: 24/05/2009   Anticipated Clear Time: 09:09  
     
  Incident Headline: : MANCHESTER WOODLEY MUX 101 : PARTIAL LOSS OF SERVICE  
     
  Incident Details: At the moment some of your Broadband End Users will be experiencing a loss of Broadband service.


 
  Progress Details: BT is making progress towards full restoration of Service.
Latest Update:

Service has been restored as of 06:09, we are now monitoring for a stability period of 3 hours.
-----------------------------------
Further updates will be provided as soon as possible.

 
  Dialling Codes Affected:
016121016128016129016135016140
016143016149016161016135
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
System Time Stamp: 24/05/2009 06:34

Broadband Incident Report : : MANCHESTER RINGWAY MUX 101 & MANCHESTER STEPPING HILL MUX 101: LOSS OF SERVICE : Reference 13122 : Issue 3 :

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
--------------------------------------------------------------

  BT Wholesale - Broadband Incident Report  
     
  Please read the following incident report as it could have an impact on some of your end users  
     
  BT Incident Reference: 13122   Issue : 3  
  Detected Date: 24/05/2009   Detected Time: 02:00  
  Start Date: 24/05/2009   Start Time: 01:25  
  Anticipated Clear Date: 24/05/2009   Anticipated Clear Time: 09:09  
     
  Incident Headline: : MANCHESTER RINGWAY MUX 101 & MANCHESTER STEPPING HILL MUX 101: LOSS OF SERVICE  
     
  Incident Details: At the moment some of your Broadband End Users will be experiencing a loss of Broadband service.


 
  Progress Details: BT is making progress towards full restoration of Service.
Latest Update:

Service has been restored as of 06:09, we are now monitoring for a stability period of 3 hours.
-----------------------------------
Further updates will be provided as soon as possible.

 
  Dialling Codes Affected:
0161016121016128016129016135
016141016145016148016161016166
016190016198016148016161
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
System Time Stamp: 24/05/2009 06:30

Broadband Incident Report : : MANCHESTER WOODLEY MUX 101 : PARTIAL LOSS OF SERVICE : Reference 13128 : Issue 2 :

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
--------------------------------------------------------------

  BT Wholesale - Broadband Incident Report  
     
  Please read the following incident report as it could have an impact on some of your end users  
     
  BT Incident Reference: 13128   Issue : 2  
  Detected Date: 24/05/2009   Detected Time: 03:20  
  Start Date: 24/05/2009   Start Time: 01:19  
  Anticipated Clear Date: 24/05/2009   Anticipated Clear Time: 06:00  
     
  Incident Headline: : MANCHESTER WOODLEY MUX 101 : PARTIAL LOSS OF SERVICE  
     
  Incident Details: At the moment some of your Broadband End Users will be experiencing a loss of Broadband service.


 
  Progress Details: BT is making progress towards full restoration of Service.
Latest Update:
Operational teams are carrying out remote diagnostics.
Further updates will be provided as soon as possible.

 
  Dialling Codes Affected:
016121016128016129016135016140
016143016149016161016135
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
System Time Stamp: 24/05/2009 04:14

Broadband Incident Report : : MANCHESTER RINGWAY MUX 101 & MANCHESTER STEPPING HILL MUX 101: LOSS OF SERVICE : Reference 13122 : Issue 2 :

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
--------------------------------------------------------------

  BT Wholesale - Broadband Incident Report  
     
  Please read the following incident report as it could have an impact on some of your end users  
     
  BT Incident Reference: 13122   Issue : 2  
  Detected Date: 24/05/2009   Detected Time: 02:00  
  Start Date: 24/05/2009   Start Time: 01:25  
  Anticipated Clear Date: 24/05/2009   Anticipated Clear Time: 06:00  
     
  Incident Headline: : MANCHESTER RINGWAY MUX 101 & MANCHESTER STEPPING HILL MUX 101: LOSS OF SERVICE  
     
  Incident Details: At the moment some of your Broadband End Users will be experiencing a loss of Broadband service.


 
  Progress Details: BT is making progress towards full restoration of Service.
Latest Update:



Operational teams are carrying out remote diagnostics.

Further updates will be provided as soon as possible.

 
  Dialling Codes Affected:
0161016121016128016129016135
016141016145016148016161016166
016190016198016148016161
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
System Time Stamp: 24/05/2009 04:11

Broadband Incident Report : : MANCHESTER WOODLEY MUX 101 : PARTIAL LOSS OF SERVICE : Reference 13128 : Issue 1 :

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
--------------------------------------------------------------

  BT Wholesale - Broadband Incident Report  
     
  Please read the following incident report as it could have an impact on some of your end users  
     
  BT Incident Reference: 13128   Issue : 1  
  Detected Date: 24/05/2009   Detected Time: 03:20  
  Start Date: 24/05/2009   Start Time: 01:19  
  Anticipated Clear Date: 24/05/2009   Anticipated Clear Time: 05:19  
     
  Incident Headline: : MANCHESTER WOODLEY MUX 101 : PARTIAL LOSS OF SERVICE  
     
  Incident Details: At the moment some of your Broadband End Users will be experiencing a loss of Broadband service.

For a full list of affected circuits, please log into BBCR, navigate to the MSO Fault Search report and enter the MSO reference number above.

http://www.btwholesale.com/pages/static/Applications/Orders/Broadband_Customer_Reporting.html
 
  Progress Details: Engineers are making progress towards full restoration of Service.

It is likely your Broadband End Users are experiencing one or more of the following:
Throughput related issues
Intermittent loss of synchronisation
Packet loss

Further updates will be provided as soon as possible.
 
  Dialling Codes Affected:
016121016128016129016135016140
016143016149016161016135
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
System Time Stamp: 24/05/2009 03:31

Broadband Incident Report : : MANCHESTER RINGWAY MUX 101 & MANCHESTER STEPPING HILL MUX 101: LOSS OF SERVICE : Reference 13122 : Issue 1 :

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
--------------------------------------------------------------

  BT Wholesale - Broadband Incident Report  
     
  Please read the following incident report as it could have an impact on some of your end users  
     
  BT Incident Reference: 13122   Issue : 1  
  Detected Date: 24/05/2009   Detected Time: 02:00  
  Start Date: 24/05/2009   Start Time: 01:25  
  Anticipated Clear Date: 24/05/2009   Anticipated Clear Time: 03:25  
     
  Incident Headline: : MANCHESTER RINGWAY MUX 101 & MANCHESTER STEPPING HILL MUX 101: LOSS OF SERVICE  
     
  Incident Details: At the moment some of your Broadband End Users will be experiencing a loss of Broadband service.

For a full list of affected circuits, please log into BBCR, navigate to the MSO Fault Search report and enter the MSO reference number above.

http://www.btwholesale.com/pages/static/Applications/Orders/Broadband_Customer_Reporting.html
 
  Progress Details: Engineers are making progress towards full restoration of Service.

It is likely your Broadband End Users are experiencing one or more of the following:
Throughput related issues
Intermittent loss of synchronisation
Packet loss

Further updates will be provided as soon as possible.
 
  Dialling Codes Affected:
0161016121016128016129016135
016141016145016148016161016166
016190016198016148016161
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
System Time Stamp: 24/05/2009 02:28

Broadband SERIOUS Incident Report : : KINGSTON NODE 04001 : PARTIAL LOSS OF SERVICE : Reference 13078 : Issue FINAL :

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
--------------------------------------------------------------

  BT Wholesale - Broadband SERIOUS Incident Report  
     
  Please read the following incident report as it could have an impact on some of your end users  
     
  BT Incident Reference: 13078   Issue : FINAL  
  Detected Date: 23/05/2009   Detected Time: 07:53  
  Start Date: 23/05/2009   Start Time: 03:06  
  Actual Clear Date: 23/05/2009   Actual Clear Time: 23:48  
     
  Incident Headline: : KINGSTON NODE 04001 : PARTIAL LOSS OF SERVICE  
     
  Incident Details: On 23 May 2009BT experienced some difficulties with ATM Node at Kingston
The fault was identified at 03:06 and upgraded within BT to a SI.

 
  Progress Details: Service has been restored by completing a
Node restarted , Circuits restored by Manual intervention
This issue may have been due to
Planned Works

BT regrets any inconvenience this may have caused.
 
  Dialling Codes Affected:
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.
*** PLEASE DO NOT REPLY TO THIS E-MAIL ***
System Time Stamp: 24/05/2009 00:47