  BT Incident Reference: 12611   Issue : FINAL  
  Detected Date: 04/05/2010   Detected Time: 16:09  
  Start Date: 04/05/2010   Start Time: 16:05  
  Actual Clear Date: 04/05/2010   Actual Clear Time: 18:30  
     
  Incident Headline: : EMSWORTH MUX 001 : DEGRADED SERVICE  
     
  Incident Details: Some of your Broadband End Users will have experiencied a loss of Broadband Service.
 
  Progress Details: Service has been restored by completing a
-----------------------------------
Power Cycle

This issue may have been due to
a Hardware Failure


BT regrets any inconvenience this may have caused.
 
  Dialling Codes Affected:
01243
 
     

--------------------------------------------------------------
Incident Manager - Automatic Mailer.